EasyManua.ls Logo

H3C WX Series

H3C WX Series
200 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
155
system-failure
Syntax
system-failure { maintain | reboot }
undo system-failure { maintain | reboot }
View
System view
Default Level
3: Manage level
Parameters
maintain: Specifies that when the system detects any software abnormality, it maintains
the current situation, and does not take any measure to recover itself.
reboot: Specifies that when the system detects any software abnormality, it recovers
itself through automatic reboot.
Description
Use the system-failure command to configure the exception handling method.
By default, the system adopts the reboot method to handle exceptions.
Examples
Set the exception handling method to reboot.
<Sysname> system-view
[Sysname] system-failure reboot
temperature-limit
Syntax
temperature-limit slot-number lower-value upper-value
undo temperature-limit slot-number
View
System view
Default Level
2: System level
Parameters
slot-number: Slot number.
lower-value: Lower temperature limit in Celsius degrees. The value ranges from 0 to 70.

Table of Contents

Other manuals for H3C WX Series

Related product manuals