system-failure
Syntax
system-failure { maintain | reboot }
undo system-failure { maintain | reboot }
View
System view
Default Level
3: Manage level
Parameters
maintain: Specifies that when the system detects any software abnormality, it maintains
the current situation, and does not take any measure to recover itself.
reboot: Specifies that when the system detects any software abnormality, it recovers
itself through automatic reboot.
Description
Use the system-failure command to configure the exception handling method.
By default, the system adopts the reboot method to handle exceptions.
Examples
Set the exception handling method to reboot.
<Sysname> system-view
[Sysname] system-failure reboot
temperature-limit
Syntax
temperature-limit slot-number lower-value upper-value
undo temperature-limit slot-number
View
System view
Default Level
2: System level
Parameters
slot-number: Slot number.
lower-value: Lower temperature limit in Celsius degrees. The value ranges from 0 to 70.

Table of Contents

Other manuals for H3C WX Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the H3C WX Series and is the answer not in the manual?

H3C WX Series Specifications

General IconGeneral
BrandH3C
ModelWX Series
CategoryIP Access Controllers
LanguageEnglish

Related product manuals