20
Default Level
2: System level
Parameters
None
Description
Use the return command to return to user view from current view, as you do with the
hot key Ctrl+Z.
Related commands: quit.
Examples
Return to user view from GigabitEthernet 1/0/1 view.
[Sysname-GigabitEthernet1/0/1] return
<Sysname>
screen-length disable
Syntax
screen-length disable
undo screen-length disable
View
User view
Default Level
1: Monitor level
Parameters
None
Description
Use the screen-length disable command to disable the multiple-screen output function
of the current user.
Use the undo screen-length disable command to enable the multiple-screen output
function of the current user.
By default, a login user uses the settings of the screen-length command. The default
settings of the screen-length command are: multiple-screen output is enabled and 24
lines are displayed on the next screen. (For more information about the screen-length
command, see User Interface in the Fundamentals Command Reference.)
This command is applicable to the current user only and when a user re-logs in, the
settings restore to the system default.