168
The current system time and date are decided by the clock datetime, clock summer-
time one-off (or clock summer-time repeating), clock timezone. For more information
about the rules, see Basic System Configuration in the Fundamentals Configuration
Guide.
Related commands: clock datetime, clock summer-time one-off, clock summer-time
repeating, and clock timezone.
Examples
Display the current time and date.
<Sysname> display clock
09:41:23 UTC Thu 12/15/2005
display configure-user
Syntax
display configure-user
View
Any view
Default Level
1: Monitor level
Parameters
None
Description
Use the display configure-user command to display the users that have logged in to
the AC and are not in user view.
Related commands: configure-user count.
Examples
Display the users entering system view at the same time.
<Sysname> display configure-user
The information of current configuration user(s):
Idx UI Delay Type Userlevel
+ 1 VTY 0 01:10:16 TEL 3
+ 2 VTY 1 00:00:00 TEL 3
Following are more details.
VTY 0 :
User name: admin
Location: 192.168.1.59
VTY 1 :
User name: admin