Chapter 7 Device Configuring Using EMS Physical Input Ports and Slots
© 2012 Harmonic Inc. 79 ProView 7000 v.2.6, Rev. E
Carrier Frequency properties – Radio buttons selection, therefore only one is selected at a
time. Changing the value on one option, changes the other one automatically:
L-Band Frequency Range – Sets the L-Band frequency of the receiver local oscillator.
Range: 950,000 – 2,150,000 (in kHz), adjustable in 125 kHz steps.
Frequency for the band selected in LNB – Sets the frequency of the satellite, according
to the satellite transmitting frequency, adjustable in .125 kHz steps.
LNB (Low Noise Block) Properties:
Polarization – Antenna polarization. Options:
13V (Vertical)
18V (Horizontal)
•Off
LNB Frequency Band – The default is Universal. Options:
Universal (9.75, 10.6)
Universal Wide (9.75, 10.75)
•Ku
•C
LNB Local Oscillator Frequency (kHz)
For Universal and Universal Wide satellite frequencies, the LNB Local Oscillator
Frequency is set according to the 22 kHz Tone setting.
For K
u
band, adjustable, in the 8.5 GHz – 13 GHz range, in 125 kHz steps.
For C band, adjustable, in the 5 GHz – 6 GHz range, in 125 kHz steps.
22 kHz ToneLow Band or High Band selectable for Universal and Universal Wide
satellite frequencies (not applicable for K
u
band and C band frequencies and not
displayed when K
u
or C band are selected)