Chapter 7 Device Configuring Using EMS Physical Input Ports and Slots
© 2012 Harmonic Inc. 79 ProView 7000 v.2.6, Rev. E
■ Carrier Frequency properties – Radio buttons selection, therefore only one is selected at a
time. Changing the value on one option, changes the other one automatically:
❑ L-Band Frequency Range – Sets the L-Band frequency of the receiver local oscillator.
Range: 950,000 – 2,150,000 (in kHz), adjustable in 125 kHz steps.
❑ Frequency for the band selected in LNB – Sets the frequency of the satellite, according
to the satellite transmitting frequency, adjustable in .125 kHz steps.
■ LNB (Low Noise Block) Properties:
❑ Polarization – Antenna polarization. Options:
• 13V (Vertical)
• 18V (Horizontal)
•Off
❑ LNB Frequency Band – The default is Universal. Options:
• Universal (9.75, 10.6)
• Universal Wide (9.75, 10.75)
•Ku
•C
❑ LNB Local Oscillator Frequency (kHz) –
For Universal and Universal Wide satellite frequencies, the LNB Local Oscillator
Frequency is set according to the 22 kHz Tone setting.
For K
u
band, adjustable, in the 8.5 GHz – 13 GHz range, in 125 kHz steps.
For C band, adjustable, in the 5 GHz – 6 GHz range, in 125 kHz steps.
❑ 22 kHz Tone – Low Band or High Band selectable for Universal and Universal Wide
satellite frequencies (not applicable for K
u
band and C band frequencies and not
displayed when K
u