Continuous operating
time
Battery With one Z1007 Battery Pack: Approx. 2 h
(reference value at 23°C)
With two Z1007 Battery Packs: Approx. 4 h
(reference value at 23°C)
Conditions: With one U8551 Universal Unit connected, backlight
Charging functionality Charging is available when the Z1007 Battery Pack is attached and the AC Adapter is
connected.
Charging time: Approx. 7 h (reference value at 23°C)
-4. Interface specications
The LAN interface and USB interface (function) cannot be used at the same time.
LAN interface LAN IEEE 802.3 Ethernet, automatic 100Base-TX/1000Base-T
detection
Auto MDI-X, DHCP, DNS support
Connector RJ-45
Maximum cable length 100 m
LAN functionality Acquiring data and setting recording conditions with the Logger
Utility
communications commands
USB Drive
HTTP server function
Control mode (one instrument)
Displaying screen and remotely controlling instrument and
modules, displaying current measured values, starting/
comment, updating instrument and modules
Browsing mode (up to four instruments)
Displaying screen, current measured values, measurement
status, and comments
Email transmission
The instrument will send emails at a regular interval and at the
following events: start trigger, stop trigger, alarm, power outage
communications interruption, and battery low.
Attachment of instantaneous value data can be enabled or
disabled.
Emails can be sent regularly at the following intervals: 30 min.,
1 h, 12 h, 1 day.
XCP on Ethernet
Measurement mode XCP Slave function support only
ASAM e.V. MCD-1 XCP v 1.5.0 compliant
NTP client function
Time synchronization with an NTP server
Regular synchronization intervals: 1
h, 1 day
Pre-measurement synchronization function