MARKer[nl:MODE
FREQuency
MARKerCnl
[:STATel
OFF
POWer:ALC:BANDwidth:AUTO ON
POWer:ALC:CFACtor -16 DBM
POWer:ALC[:SOURce]
INTernal
POWer:AMPLifier:STATE:AUTO ON
POWer:ATTenuation:AUTO ON
POWer:CENTerO DBM
POWer[:LEVell
0 DBM
POWer:MODEFIXed
POWer:SLOPe 0
POWer:SLOPe:STATe OFF
POWer:SPAN 0 DB
POWer:STARt 0 DBM
POWer:STATe OFF
POWer:STEP:AUTO ON
POWer:STEP[:INCRement]
10 DB
POWer:STOP 0 DBM
PULM:SOURce
SCALar
PULM:STATe OFF
ROSCillator:SOURce:AUTO
ON
SWEep:DWELl
100
ps
SWEep:DWELl:AUTO
OFF
SWEep:POINts 11
SWEep:STEP value is
(StopMAX-StartMIN)/lO
SWEep:TIME
MINimum
SWEep:TIME:AUTO ON
SWEep:TIME:LLIMit
10ms
SWEep:GENeration
ANALog
SWEep:MODEAUTO
SWEep:MANual:POINt 1
SWEep:MANual[:RELativel
0.50
SWEep:MARKer:STATe OFF
SYSTem:ALTernate 1
SYSTem:ALTernate:STATe OFF
SYSTem:COMMunicate:GPIB:ADDRess 19
SYSTem:MMHead:SELect:AUTO ON
SYSTem:SECurity:COUNt 1
UNIT:POWerDBM
l
*SAV
<num>
The present instrument state
is stored in the specified memory
register.
The
acceptable numeric range is from 1 to 8.
An
execution
error occurs if you try to save state 0.
l
*SRE
Cnum>
l
*SRE?
Sets
and queries the value of the Service Request Enable Register.
S-14 Operating and Programming Reference