Figure 98 Disabling circular logging
Problem
Omnicreatedl cannot create a backup specification and the session is aborted
The following error is reported:
[ERROR] Could not obtain any data for backup from host app_sys.
Make sure the Exchange server is running and Data Protector Exchange
Integration installed.
Actions
• If the application is cluster-aware, specify the -virtualSrv parameter.
• Check the user rights on the application system client. You must have the Save
backup specification user right to create and save a backup specification.