621
Use undo fin-flood detect non-specific to restore the default.
Syntax
fin-flood detect non-specific
undo fin-flood detect non-specific
Default
FIN flood attack detection is not enabled for non-specific IP addresses.
Views
Attack defense policy view
Predefined user roles
network-admin
Usage guidelines
This command enables global FIN flood attack detection. It applies to all IP addresses except for those
specified by the fin-flood detect command. The system uses the global trigger threshold set by the
fin-flood threshold command and global actions specified by the fin-flood action command.
Examples
# Enable FIN flood attack detection for non-specific IP addresses in attack defense policy atk-policy-1.
<Sysname> system-view
[Sysname] attack-defense policy atk-policy-1
[Sysname-attack-defense-policy-atk-policy-1] fin-flood detect non-specific
Related commands
fin-flood action
fin-flood detect
fin-flood threshold
fin-flood threshold
Use fin-flood threshold to set the global threshold for triggering FIN flood attack prevention.
Use undo fin-flood threshold to restore the default.
Syntax
fin-flood threshold threshold-value
undo fin-flood threshold
Default
The global threshold is 1000 for triggering FIN flood attack prevention.
Views
Attack defense policy view
Predefined user roles
network-admin

Table of Contents

Other manuals for HP MSR SERIES

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HP MSR SERIES and is the answer not in the manual?

HP MSR SERIES Specifications

General IconGeneral
Product SeriesMSR Series
ManufacturerHP
CategoryNetwork Router
PortsVaries by model
WAN InterfacesVaries by model
LAN InterfacesVaries by model
VPN SupportYes
FirewallYes
DimensionsVaries by model
WeightVaries by model
Wireless SupportVaries by model
ManagementWeb-based, CLI
Power SupplyVaries by model
Operating Temperature0°C to 45°C
Storage Temperature-40°C to 70°C
Humidity5% to 95% non-condensing

Related product manuals