Installation and Setup
Powermax45 XP Operator Manual 809240 33
Extension cord recommendations
Use an extension cord that:
Is an appropriate wire gauge for the cord length and system voltage
Meets national and local codes
Extension cords can cause the machine to receive less input voltage than
the output of the circuit. This can limit the operation of your system.
Generator recommendations
Generators used with this system must meet the voltage requirements in the following table and in
Hypertherm plasma power supply ratings on page 21.
Adjust the cutting current (amperage) as needed based on the rating, age, and condition of
the generator.
Input voltage Phase
Cord Length Cord Gauge
200– 240VAC 1
up to 15 m (50 feet) 10 mm
2
(8 AWG)
15–30m (50–100feet) 16mm
2
(6 AWG)
30 – 45 m (100 – 150 feet) 25 mm
2
(4 AWG)
380 – 480 VAC 3
up to 15 m (50 feet) 4 mm
2
(12 AWG)
15 – 45 m (50 – 150 feet) 6 mm
2
(10 AWG)
Engine drive rating Plasma system output current Performance (arc stretch)
10 kW 45 A Full
8kW 45A Limited
6kW 30A Full