After
completing the tape read program, the
first
file
of
the
CE
diagnostic cartridge is loaded into
read/write
storage and the following information is displayed:
DCP2
MENU
EC.XXXXXX
800
PRINTER
MDI
820
COMMUNICATIONS/SERIAL
I/O
MDI
840
AUXILIARY
TAPE
MDI
860
TAPE
WRITE
MDI
890
DIAGNOSTIC
ROUTINE
CHART
ENTER
THE
MDI
NUMBER
TO
BE
RUN
ENTER
'0'
IF
THE
OPTIONS
ARE
TO
BE
DISPLAYED
§fATUS:
ENTER
REPLY
XXX
XXX
is
tne current
EC
number
of
this
CE
diagnostic cartridge.
The leftmost dash before the words
ENTER
THE MOl
NUMBER TO
BE
RUN
flashes
to
indicate the position
of
the next character
to
be
entered from the keyboard. The
procedure
for
entering the MOl number is found under
MOl in this section.
MOl
(MAPs
and
Diagnostics
Integrated)
MOl is MAPs and diagnostic programs integrated into a
single maintenance approach. MOl,
with
the display and
the keyboard, allows you
to
isolate machine failures by
responding
to
information on the display screen.
Questions on the display require a response via the
keyboard. The MOl goes
to
the next question or section
based on the keyboard input.
Loading MOl Sections
To load MOl sections, select the section from the
OCP2
menu, enter the section number, and press EXECUTE.
An 0 {letter) can be entered along with the
MOl
sections number (but on the next line)
to
select a special
option or
to
alter a previously selected special option.
Then, pressing
EXECUTE
displays the MOl options.
5100 Diagnostics Overview 3-29