WindO/I-NV4 Users Manual 20-51
5 Script Coding Examples
20
Script
String operations
When using functions that handle string data, check the Storage Method of string data setting in the project
settings.
For details, refer to Chapter 4 “3.1 System Tab” on page 4-25.
Script
Operation description
Stores in order from LDR100 character count 3 (3 characters worth) from start position 2 (starting from 0, so the 3rd
character) of the string “ABCDEFG” that starts from LDR200.
Copy from string “ABCDEFG” at start position 2, character count 3
Script
Copy from string “ABCDEFG” at start position 1, character count 4
Example 5.7.26 Copy a string
STRCUT([LDR 100], [LDR 200], 2, 3);
The start position can be specified in the range from 0 to 127, the character count can be specified in the
range from 1 to 128.
STRCUT([LDR 100], [LDR 200], 1, 4);
Device address Stored value
Start
position
Character count
Device address Stored value
LDR200
Upper byte
'A' = 0x41 0
LDR100
Upper byte
'C' = 0x43
Lower byte
'B' = 0x42 1
Lower byte
'D' = 0x44
LDR201
Upper byte
'C' = 0x43
2
LDR101
Upper byte
'E' = 0x45
Lower byte
'D' = 0x44 3
Lower byte
0x00
Terminating character
LDR202
Upper byte
'E' = 0x45 4
Lower byte
'F' = 0x46 5
LDR203
Upper byte
'G' = 0x47 :
Lower byte
0x00
Terminating character
3 characters
Device address Stored value
Start
position
Character count
Device address Stored value
LDR200
Upper byte
'A' = 0x41 0
LDR100
Upper byte
'B' = 0x42
Lower byte
'B' = 0x42
1
Lower byte
'C' = 0x43
LDR201
Upper byte
'C' = 0x43
2
LDR101
Upper byte
'D' = 0x44
Lower byte
'D' = 0x44 3
Lower byte
'E' = 0x45
LDR202
Upper byte
'E' = 0x45 4
LDR102
Upper byte
0x00
Terminating character
Lower byte
'F' = 0x46 5
Lower byte
0x00
LDR203
Upper byte
'G' = 0x47 :
Lower byte
0x00
Terminating character
4 characters

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the IDEC MICRO/I HG1P-ST32 Series and is the answer not in the manual?

IDEC MICRO/I HG1P-ST32 Series Specifications

General IconGeneral
BrandIDEC
ModelMICRO/I HG1P-ST32 Series
CategoryControl Panel
LanguageEnglish

Related product manuals