WindO/I-NV4 Users Manual 12-59
7 Timer
12
Commands
7.1 How the Timer is Used
Starts a countdown when the trigger condition is satisfied, and writes 1 to an internal device (HMI Timer Relay LTC)
once the set time has elapsed.
7Timer
HG3G
HG2G-5FHG5G-V HG4G-V HG3G-V HG2G-V HG2G-5T
HG4G HG1G HG1P
MICRO/I
LTD0
0
1
LTC0:
0
LTC0:
1
1999
1998 999 1
0
LTD0
Start countdown Set me
has elapsed
Condition
Satisfied
Satisfied
Satisfied
Start
countdown
0 0 1 0
Writes 1
to LTC0
Writes the
preset value
to LTD0 and 0
to LTC0
State of condition
Action
HMI Timer Relay
LTC0 value
HMI Timer Current Value
LTD0 value
1999
1999
1998 999 1
1999
0
Condition Condition Condition Condition
Not satisfiedNot satisfiedNot satisfied SatisfiedSatisfiedSatisfied SatisfiedSatisfiedSatisfied
Not satisfiedNot satisfiedNot satisfied
The HMI Timer Relay LTC is an internal device (bit device) that changes to 1 once the time set for the
timer has elapsed.
The HMI Timer Current Value LTD is an internal device (word device) that stores current values for the
timer.
Once switched to the screen that the timer has been placed in, the following values will be given
regardless of the whether the trigger condition is satisfied or not satisfied.
-HMI Timer Relay LTC: 0
- HMI Timer Current Value LTD: Preset Value