WindO/I-NV4 User’s Manual 3-61
5 User Communication
3
Communication
• Bytes and BCC data
When the converted data is 3034h, the data appended to the transmission data is as follows.
• When Calculation Type is Modbus ASCII (LCR)
When the BCC calculation result is 4241h after Hexadecimal to ASCII conversion the resulting two bytes of
data is appended to the transmission data.
• When Calculation Type is Modbus RTU (CRC)
When the BCC calculation result is BA30h with no conversion the two bytes of data is appended to the
transmission data.
0
(30h)
4
(34h)
1 byte
BCC data
(Second byte) (First byte)
Converted data
4
(34h)
0
(30h)
4
(34h)
BCC data
0
(30h)
4
(34h)
2 bytes
Converted data
(Second byte) (First byte)
B
(42h)
A
(41h)
B
(42h)
A
(41h)
BCC data
4241h
Hexadecimal to ASCII
Data
2 bytes
Converted data
(Second byte) (First byte)
BAh
30h
BAh
30h
BA30h
No conversion
BCC data
Data
2 bytes
Converted data
(Second byte) (First byte)

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the IDEC MICRO/I HG1P-ST32 Series and is the answer not in the manual?

IDEC MICRO/I HG1P-ST32 Series Specifications

General IconGeneral
BrandIDEC
ModelMICRO/I HG1P-ST32 Series
CategoryControl Panel
LanguageEnglish

Related product manuals