Parameter Group
-99-
AC-21
Extension card 2 - AI2 displayed voltage 1
Address:
44053
Min.:
0.000
Unit:
V
Max.: 12.000 Data type: UInt16
Default:
2.000
Change:
At once
Value Range:
0.000 V to 12.000 V
Description
When analog voltage correction is conducted on AI1, a correction curve is obtained based on two
points, each of which corresponds to a measured voltage and a displayed voltage. The measured
voltage is the voltage measured using a meter, and the displayed voltage is the AI1 voltage before
correction (U4-13).
AC-22
Extension card 2 - AI2 measured voltage 2
Address:
44054
Min.:
0.000
Unit:
V
Max.: 12.000 Data type: UInt16
Default:
2.000
Change:
At once
Value Range:
0.000 V to 12.000 V
Description
When analog voltage correction is conducted on AI1, a correction curve is obtained based on two
points, each of which corresponds to a measured voltage and a displayed voltage. The measured
voltage is the voltage measured using a meter, and the displayed voltage is the AI1 voltage before
correction (U4-13).
AC-23
Extension card 2 - AI2 displayed voltage 2
Address:
44055
Min.:
0.000
Unit:
V
Max.: 12.000 Data type: UInt16
Default:
2.000
Change:
At once
Value Range:
0.000 V to 12.000 V
Description
When analog voltage correction is conducted on AI1, a correction curve is obtained based on two
points, each of which corresponds to a measured voltage and a displayed voltage. The measured
voltage is the voltage measured using a meter, and the displayed voltage is the AI1 voltage before
correction (U4-13).
AC-24
Extension card 3 - AI1 measured voltage 1
Address:
44056
Min.:
0.000
Unit:
V
Max.: 12.000 Data type: UInt16
Default:
2.000
Change:
At once
Value Range:
0.000 V to 12.000 V
Description
Extension card 3 - AI1 measured voltage 1
AC-25
Extension card 3 - AI1 measured voltage 1
Address:
44057