Parameter Group
-90-
Min.:
0
Unit:
-
Max.: 5 Data type: UInt16
Default:
0
Change:
At stop
Value Range:
0: Voltage input
1: Current input
2: PT100 input
3: PT1000 input
4: KTY84 input
5: PTC130 input
Description
AI1 input
A1-11
AI2 input
Address:
41227
Min.:
0
Unit:
-
Max.: 5 Data type: UInt16
Default:
0
Change:
At stop
Value Range:
0: Voltage input
1: Current input
2: PT100 input
3: PT1000 input
4: KTY84 input
5: PTC130 input
Description
AI2 input
1.10 A2: I/O Extension Card 1 Function Parameters
A2-00
Extension card 1 - filter time of DI1 to DI4
Address:
41472
Min.:
0.000
Unit:
s
Max.: 5.000 Data type: UInt16
Default:
0.010
Change:
At once
Value Range:
0.000s to 5.000s
Description
Extension card 1 - filter time of DI1 to DI4
A2-01
Extension card 1 - filter time of DI5 to DI8
Address:
41473
Min.:
0.000
Unit:
s
Max.: 5.000 Data type: UInt16
Default:
0.010
Change:
At once
Value Range:
0.000s to 5.000s
Description
Extension card 1 - filter time of DI5 to DI8