Function Applications
-539-
Maximum distance of the linear servo motor: 30 mm
4.8 Monitoring
The monitoring function enables you to view the AC drive state in the LED display area on the
operating panel. You can monitor AC drive status in the following two ways:
1. In the stop or running state, you can view multiple state parameters by pressing
on the
operating panel to switch between bytes of F7-03, F7-04, and F7-05.
In the running state, 32 running state parameters are available. You can select whether to display a
parameter by setting the corresponding binary bit of F7-03 (LED display 1 in running state) and F7-04
(LED display 2 in running state). In the stop state, 13 stop state parameters are available. You can
select whether to display a parameter by setting the corresponding binary bit of F7-05 (LED display
in stop state).
For example, to view the running frequency, bus voltage, output voltage, output current, output
power, and PID reference on the panel, perform the following operations:
Set corresponding bits to 1 according to the mapping between each byte of F7-03 (LED display in
running state) and the preceding parameters. Convert the binary number to a hexadecimal
equivalent, and set the hexadecimal number in F7-03. For details about the conversion, see the
following table. Then you can press
on the operating panel and switch between bytes of F7-
03 to view the related parameter values.
You can view other monitoring parameters in the same way. The following table describes the
mapping between the monitoring parameters and bytes of F7-03, F7-04, and F7-05.