Parameter Group
-339-
FD-14
Number of CAN frames received per unit time
Address:
64782
Min.:
0
Unit:
-
Max.:
65535
Data type: UInt16
Default:
1
Change: Unchangeable
Value Range:
0 to 65535
Description
This parameter is used to monitor the bus load. It defines the number of CAN frames received by the
station per second.
FD-19
CAN communication failure coefficient
Address:
64787
Min.:
1
Unit:
-
Max.: 15 Data type: UInt16
Default:
1
Change:
At stop
Value Range:
1 to 15
Description
This parameter defines the CAN communication disconnection coefficient.
FD-92
Communication version
Address:
64860
Min.:
0.00
Unit:
-
Max.: 655.35 Data type: UInt16
Default:
0.00
Change: Unchangeable
Value Range:
0.00 to 655.35
Description
This parameter shows the communication software version of the AC drive.
2.15 FE: User-Defined Parameters
FE-00
User-defined parameter 0
Address:
65024
Min.:
0
Unit:
-
Max.: 0 Data type: UInt16
Default:
0
Change:
At once
Value Range:
-
Description
Group FE consists of user-defined parameters. Users can add commonly used parameters to group FE
for easier check and modification.
FE-01
User-defined parameter 1
Address:
65025
Min.:
0
Unit:
-
Max.: 0 Data type: UInt16
Default:
0
Change:
At once
Value Range: