Parameter Group
-338-
Ones: CANopen
0: Stop
1: Initializing
2: Pre-running
8: Running
Tens: CANlink
0: Stop
1: Initializing
2: Pre-running
8: Running
Description
This read-only parameter is used to monitor the communication status.
FD-10
Switchover between CANopen and CANlink
Address:
64778
Min.:
1
Unit:
-
Max.: 2 Data type: UInt16
Default:
1
Change: Unchangeable
Value Range:
1: CANopen
2: CANlink
Description
This parameter shows the CAN communication protocol for the power supply unit.
If the value is 1, the CANopen communication or communication extension card mode is used. If the
value is 2, CANlink communication is used.
This parameter is read-only. To select a communication protocol, use Fd-10 of the power supply unit.
FD-11 CANopen402
Address:
64779
Min.:
0
Unit:
-
Max.: 1 Data type: UInt16
Default:
0
Change:
At stop
Value Range:
0: Disabled
1: Enabled
Description
This parameter defines whether to enable the CANopen mode.
When it is set to 0, the normal mode is used. When it is set to 1, the CiA402 mode is enabled.
FD-13
CAN station number
Address:
64781
Min.:
1
Unit:
-
Max.: 127 Data type: UInt16
Default:
1
Change:
At stop
Value Range:
1 to 127
Description
This parameter defines the CAN station number, including station numbers for CANlink and CANopen
communication. In the same network, all station numbers must be unique. Otherwise,
communication will fail.