Parameter Group
-346-
FE-30
User-defined parameter 30
Address:
65054
Min.:
0
Unit:
-
Max.: 0 Data type: UInt16
Default:
0
Change:
At once
Value Range:
-
Description
Group FE consists of user-defined parameters. Users can add commonly used parameters to group FE
for easier check and modification.
FE-31
User-defined parameter 31
Address:
65055
Min.:
0
Unit:
-
Max.: 0 Data type: UInt16
Default:
0
Change:
At once
Value Range:
-
Description
Group FE consists of user-defined parameters. Users can add commonly used parameters to group FE
for easier check and modification.
2.16 FP: User Parameters
FP-00
User password
Address:
7936
Min.:
0
Unit:
-
Max.: 65535 Data type: UInt16
Default:
0
Change: Unchangeable
Value Range:
0 to 65535
Description
After the password is set, the password is required when the operating panel of the power supply unit
is used to control the drive unit.
FP-01
Parameter initialization
Address:
7937
Min.:
0
Unit:
-
Max.: 501 Data type: UInt16
Default:
1
Change:
At once
Value Range:
0: No operation
1: Restore factory defaults mode 1
2: Clear records
4: Back up current user parameters
501: Restore user backup parameters
Description
This parameter is used to set the corresponding action upon parameter initialization of the AC drive.
0: No operation
The AC drive does not perform any operation.

Table of Contents

Other manuals for Inovance MD800 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Inovance MD800 Series and is the answer not in the manual?

Inovance MD800 Series Specifications

General IconGeneral
Input Voltage3-phase 380V AC ±15%
Output Voltage0 to input voltage
Output CurrentDepends on model
Power Range0.75 kW to 500 kW
Control ModeV/F control, vector control
CommunicationModbus
ProtectionOvercurrent, overvoltage, undervoltage, overload, overheat
Operating Temperature-10°C to +50°C
Storage Temperature-20°C to 60°C
Humidity5% to 95% (non-condensing)
AltitudeUp to 1000m without derating