Function Applications
-531-
Item
Test Condition
Vibration duration 10 times on each of the three mutually perpendicular axes
Axis
X, Y, Z
Installation According to the manufacturer's specifications
4.7.3 Installation
Before use, configure the two independent inputs STO1/STO2 as two-channel inputs for the STO
function.
For devices with the STO function, if the STO function is not required, STO1/STO2 can be connected to
24V at the same time to ensure normal operation of the devices.
4.7.4 Terminals and Connection
Terminal Arrangement and Definitions
The STO function is integrated in the drive unit, and its terminal arrangement and definitions are as
follows.
Figure 4-67 STO terminal arrangement of the drive unit (single-axis)
Table 4–40 STO terminal (optional) description of the drive unit (single-axis)
Appearance
Terminal Code Terminal Name Specifications
STO1
STO channel 1 power supply+
24 V input
1GND
STO channel 1 power supply-
STO2
STO channel 2 power supply+
2GND
STO channel 2 power supply-