Function Applications
-429-
Figure 4-10 Main frequency reference selection
Para. No. Name
Value Range
Default
F0-03
Main frequency source X
0: Digital setting (preset frequency (F0-08) that
can be changed by pressing UP/DOWN, non-
retentive upon power failure)
1: Digital setting (preset frequency (F0-08) that
can be changed by pressing UP/DOWN, retentive
upon power failure)
2: AI1
3: AI2
4: AI3
6: Multi-reference
7: Simple PLC
8: PID
9: Communication
10: Reserved
0
4.1.2.3 Operating Panel Control
There are two ways to set the main frequency by using the operating panel: