Parameter Group
-244-
Description
Minimum motoring torque current
F3-30
Maximum generating torque current
Address:
62238
Min.:
10
Unit:
-
Max.: 100 Data type: UInt16
Default:
20
Change:
At stop
Value Range:
10 to 100
Description
Maximum generating torque current
F3-31
Automatic frequency rise Kp
Address:
62239
Min.:
0
Unit:
-
Max.: 100 Data type: UInt16
Default:
50
Change:
At once
Value Range:
0 to 100
Description
Automatic frequency rise Kp
F3-32
Automatic frequency rise Ki
Address:
62240
Min.:
0
Unit:
-
Max.: 100 Data type: UInt16
Default:
50
Change:
At once
Value Range:
0 to 100
Description
Automatic frequency rise Ki
F3-33
Online torque compensation gain
Address:
62241
Min.:
80
Unit:
-
Max.: 150 Data type: UInt16
Default:
100
Change:
At stop
Value Range:
80 to 150
Description
This parameter defines the automatic torque boost gain. The automatic torque boost function takes
effect when the value of this parameter is greater than or equal to 100. The default value is
recommended.
2.5 F4: Input Terminals
F4-00
DI1 hardware source
Address:
62464
Min.:
0
Unit:
-