Parameter Group
-351-
Value Range:
0.0s to 6500.0s
Description
This parameter defines the frequency deceleration time, which is valid in torque control mode.
A0-14
Torque mode switchover
Address:
40974
Min.:
0
Unit:
-
Max.: 2 Data type: UInt16
Default:
1
Change:
At stop
Value Range:
0: Not switched
1: Switched to speed mode upon stop
2: Target torque changed to 0 upon stop
Description
This parameter is used to switch the torque mode. If it is set to 0, no switchover is performed. If it is
set to 1, the mode is switched to the speed mode upon stop. If it is set to 2, the target torque is
changed to 0 upon stop.
2.18 A1: VDI/VDO
A1-00
VDI1 function
Address:
41216
Min.:
0
Unit:
-
Max.: 63 Data type: UInt16
Default:
0
Change:
At stop
Value Range:
0 to 63
Description
VDI1 to VDI5 can be used as multi-functional DIs. The functions 0 to 63 are the same as those of
common DIs. For details, see the description of F4-01.
A1-01
VDI2 function
Address:
41217
Min.:
0
Unit:
-
Max.: 63 Data type: UInt16
Default:
0
Change:
At stop
Value Range:
Same as A1-00
Description
Same as A1-00
A1-02
VDI3 function
Address:
41218
Min.:
0
Unit:
-
Max.:
63
Data type: UInt16
Default:
0
Change:
At stop
Value Range:
Same as A1-00