Parameter Group
-93-
0: Voltage input
1: Current input
2: PT100 input
3: PT1000 input
4: KTY84 input
5: PTC130 input
Description
AI1 input
A3-11
AI2 input
Address:
41739
Min.:
0
Unit:
-
Max.: 5 Data type: UInt16
Default:
0
Change:
At stop
Value Range:
0: Voltage input
1: Current input
2: PT100 input
3: PT1000 input
4: KTY84 input
5: PTC130 input
Description
AI2 input
1.12 AC: AI Correction Coefficient
AC-00
Power supply unit - AI1 measured voltage 1
Address:
44032
Min.:
0.000
Unit:
V
Max.: 12.000 Data type: UInt16
Default:
2.000
Change:
At once
Value Range:
0.000 V to 12.000 V
Description
When analog voltage correction is conducted on AI1, a correction curve is obtained based on two
points, each of which corresponds to a measured voltage and a displayed voltage. The measured
voltage is the voltage measured using a meter, and the displayed voltage is the AI1 voltage before
correction (U2-12).
AC-01
Power supply unit - AI1 displayed voltage 1
Address:
44033
Min.:
0.000
Unit:
V
Max.: 12.000 Data type: UInt16
Default:
2.000
Change:
At once
Value Range:
0.000 V to 12.000 V