Parameter Group
-235-
Min.:
0
Unit:
-
Max.: 1 Data type: UInt16
Default:
0
Change:
At stop
Value Range:
0: Disabled
1: Enabled
Description
This parameter defines whether to enable power limit during generating.
F2-54
Power limit during generating
Address:
62006
Min.:
0.0
Unit:
%
Max.: 200.0 Data type: UInt16
Default:
0.0
Change:
At stop
Value Range:
0.0% to 200.0%
Description
This parameter defines the power limit during generating, which can limit the power during
generating according to actual applications.
F2-55
Flux closed loop mode
Address:
62007
Min.:
0
Unit:
-
Max.: 1111 Data type: UInt16
Default:
1010
Change:
At stop
Value Range:
0 to 1111
Description
This parameter defines the flux closed loop mode. The default value is recommended.
F2-56
AC drive output current upper limit
Address:
62008
Min.:
0.0
Unit:
%
Max.: 170.0 Data type: UInt16
Default:
150.0
Change:
At stop
Value Range:
0.0% to 170.0%
Description
This parameter defines the output current upper limit of the AC drive. The default value is
recommended.