Parameter Group
-83-
FD-98
Station number of device connected to reserved slot 6
Address:
64866
Min.:
0
Unit:
-
Max.: 65535 Data type: UInt16
Default:
0
Change: Unchangeable
Value Range:
0 to 65535
Description
Station number of device connected to reserved slot 6
FD-99
Station number of device connected to reserved slot 7
Address:
64867
Min.:
0
Unit:
-
Max.: 65535 Data type: UInt16
Default:
0
Change: Unchangeable
Value Range:
0 to 65535
Description
Station number of device connected to reserved slot 7
1.7 FP: User Password
FP-00
User password
Address:
7936
Min.:
0
Unit:
-
Max.: 65535 Data type: UInt16
Default:
0
Change:
At once
Value Range:
0 to 65535
Description
This parameter defines the user password.
FP-01
Parameter initialization
Address:
7937
Min.:
0
Unit:
-
Max.: 501 Data type: UInt16
Default:
1
Change:
At once
Value Range:
0: No operation
1: Restore factory defaults
2: Clear records
4: Back up current user parameters
501: Restore user backup parameters
Description
This parameter is used to set the corresponding action upon parameter initialization of the AC drive.
0: No operation
The AC drive does not perform any operation.
1: Restore factory defaults mode 1
Restore factory defaults (excluding parameters in groups FA and FP).