Function Applications
-471-
Table 4–21 Related parameters
Para. No. Name
Default Value Range
Description
A1-00
VDI1 function
0 0 to 60
VDI1 to VDI5 can be used as
multi-functional DIs. The
functions 0 to 60 are the same as
those of common DIs. For details,
see
4.3.1.2 Functions of DI
Terminals
on page 461
.
A1-01
VDI2 function
0 0 to 60
A1-02
VDI3 function
0 0 to 60
A1-03
VDI4 function
0 0 to 60
A1-04
VDI5 function
0 0 to 60
A1-05
VDI active state source
00000 0: A1-06
1: DO state
2: DI state
Ones: VDI1 
Tens: VDI2
Hundreds: VDI3
Thousands: VDI4
Ten thousands: VDI5
Three ways of setting VDI status
are available and can be selected
by using A1-05.
When it is set to 0, the VDI state is
determined by the binary bit of
A1-06.
When it is set to 1, the VDI state is
determined by the state (active
or inactive) of the corresponding
DO/RO. VDIx is uniquely bound to
DOx/ROx (x ranges from 1 to 5).
When it is set to 2, the VDI state is
determined by the state (active
or inactive) of the corresponding
DI. VDIx is uniquely bound to DIx
(x ranges from 1 to 5).
A1-06 VDI state 00000
0: Inactive
1: Active
Ones: VDI1
Tens: VDI2
Hundreds: VDI3
Thousands: VDI4
Ten thousands: VDI5
-
4.3.4 Analog or Temperature Input (AI)
4.3.4.1 Sources of Analog or Temperature Input Terminals
The AC drive itself has no analog or temperature input and needs to map to analog or temperature
inputs of the power supply unit or extension card. Therefore, you need to set the analog or
temperature input sources when the drive unit uses analog inputs or temperature sensors.
The analog or temperature input source is displayed as follows when you modify related parameters
on the operating panel.
Display Description
Ten thousands, thousands: I/O
Hundreds: Serial number 0 indicates the power supply unit, 1
indicates extension card 1, 2 indicates extension card 2, and so
on.
Tens, ones: Hardware terminal

Table of Contents