Parameter Group
-356-
1 to 13
Description
This parameter defines the sampling delay.
A5-06
Undervoltage threshold
Address:
42246
Min.:
150.0
Unit:
V
Max.: 455.0 Data type: UInt16
Default: Three-phase 400 V: 350.0 V Single-
phase 200 V: 200.0 V
Change:
At once
Value Range:
150.0 V to 455.0 V
Description
When the bus voltage is lower than the setpoint of A5-06, the AC drive reports E09.00.
A5-07
SVC optimization mode
Address:
42247
Min.:
0
Unit:
-
Max.: 2 Data type: UInt16
Default:
1
Change:
At stop
Value Range:
0: No optimization
1: Optimization mode 1
2: Optimization mode 2
Description
This parameter defines the SVC optimization mode.
2.20 A6: AI Curve Settings
A6-00
Curve 4 minimum input
Address:
42496
Min.:
–10.00
Unit:
V
Max.: 10.00 Data type: Int16
Default:
0.00
Change:
At once
Value Range:
-10.00 V to 10.00 V
Description
This parameter defines the x-axis of the minimum input point on AI curve 4, that is, the minimum
analog input voltage (or minimum analog input current).
A6-01
Percentage corresponding to curve 4 minimum input
Address:
42497
Min.:
–100.0
Unit:
%
Max.: 100.0 Data type: Int16
Default:
0.0
Change:
At once
Value Range:
–100.0% to 100.0%
Description
This parameter defines the y-axis of the minimum input point on AI curve 4, that is, the percentage of
the minimum analog input relative to the maximum frequency.