Parameter Group
-352-
Description
Same as A1-00
A1-03
VDI4 function
Address:
41219
Min.:
0
Unit:
-
Max.: 63 Data type: UInt16
Default:
0
Change:
At stop
Value Range:
Same as A1-00
Description
Same as A1-00
A1-04
VDI5 function
Address:
41220
Min.:
0
Unit:
-
Max.: 63 Data type: UInt16
Default:
0
Change:
At stop
Value Range:
Same as A1-00
Description
Same as A1-00
A1-05
VDI active state source
Address:
41221
Min.:
0
Unit:
-
Max.: 22222 Data type: UInt16
Default:
0
Change:
At stop
Value Range:
Ones:
0: Parameter setting (A1-06)
1: DO state
2: DI state
Tens:
0: Parameter setting (A1-06)
1: DO state
2: DI state
Hundreds:
0: Parameter setting (A1-06)
1: DO state
2: DI state
Thousands:
0: Parameter setting (A1-06)
1: DO state
2: DI state
Ten thousands:
0: Parameter setting (A1-06)
1: DO state
2: DI state
Description