Parameter Group
-347-
1: Restore factory defaults mode 1
Most of the parameters are restored to factory defaults. However, motor parameters, F0-22 (decimal
places of frequency reference), fault records, F7-09 (accumulative running time), F7-13 (accumulative
power-on time), F7-14 (accumulative power consumption), and F7-07 (IGBT heatsink temperature) are
not restored.
2: Clear records
The fault records, F7-09 (accumulative running time), F7-13 (accumulative power-on time), and F7-14
(accumulative power consumption) are cleared.
4: Back up current user parameters
The current parameter settings are backed up.
501: Restore user backup parameters
Parameters backed up by setting FP-01 to 4 are restored.
FP-02
Parameter display
Address:
7938
Min.:
0
Unit:
-
Max.: 1111 Data type: UInt16
Default:
111
Change:
At once
Value Range:
Ones: Group U
0: Hide
1: Display
Tens: Group A
0: Hide
1: Display
Hundreds: Group B
0: Hide
1: Display
Thousands: Group C
0: Hide
1: Display
Description
This parameter is used to determine whether to display the parameters of groups U, A, B, and C on
the operating panel.
FP-03
Individualized parameter display mode
Address:
7939
Min.:
0
Unit:
-
Max.: 11 Data type: UInt16
Default:
0
Change:
At once
Value Range:
Ones:
0: Hide
1: Display
Tens:
0: Hide
1: Display