Parameter Group
-115-
U0-06
Input voltage Utr
Address:
28678
Min.:
0
Unit:
V
Max.: 1000 Data type: UInt16
Default:
0
Change: Unchangeable
Value Range:
0 V to 1000 V
Description
This parameter defines the input RST voltage Utr.
U0-07
Three-phase imbalance factor
Address:
28679
Min.:
0.0
Unit:
%
Max.: 100.0 Data type: UInt16
Default:
1
Change: Unchangeable
Value Range:
0.0% to 100.0%
Description
This parameter defines the input RST imbalance factor.
U0-12
Current fault code
Address:
28684
Min.:
0
Unit:
-
Max.: 100 Data type: UInt16
Default:
0
Change: Unchangeable
Value Range:
0 to 100
Description
This parameter defines the fault code of the current fault.
U0-13
Current fault subcode
Address:
28685
Min.:
0
Unit:
-
Max.: 100 Data type: UInt16
Default:
0
Change: Unchangeable
Value Range:
0 to 100
Description
This parameter defines the subcode of the current fault.
U0-14
Current alarm code
Address:
28686
Min.:
0
Unit:
-
Max.: 100 Data type: UInt16
Default:
0
Change: Unchangeable
Value Range:
0 to 100
Description
This parameter defines the alarm code of the current alarm.
U0-15
Current alarm subcode
Address:
28687