EasyManua.ls Logo

Inovance MD800 Series - Page 122

Inovance MD800 Series
565 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Parameter Group
-121-
Max.: 65535 Data type: UInt16
Default:
0
Change: Unchangeable
Value Range:
0 to 65535
Description
This parameter shows the current hardware DO output state. Bit0 corresponds to DO1, bit1
corresponds to DO2, and so on.
U2-12
Local - AI1 input (before correction)
Address:
29196
Min.:
–10.000
Unit:
V
Max.: 10.000 Data type: Int
Default:
0.000
Change: Unchangeable
Value Range:
–10.000 V to 10.000 V
Description
This parameter shows the current AI1 input which is not corrected.
U2-13
Local - AI2 input (before correction)
Address:
29197
Min.:
–10.000
Unit:
V
Max.: 10.000 Data type: Int
Default:
0.000
Change: Unchangeable
Value Range:
–10.000 V to 10.000 V
Description
This parameter shows the current AI2 input which is not corrected.
U2-14
Local - AI1 input (after correction)
Address:
29198
Min.:
–10.00
Unit:
V
Max.: 10.00 Data type: Int
Default:
0.00
Change: Unchangeable
Value Range:
–10.00 V to 10.00 V
Description
This parameter shows the current corrected AI1 input.
U2-15
Local - AI2 input (after correction)
Address:
29199
Min.:
–10.00
Unit:
V
Max.: 10.00 Data type: Int
Default:
0.00
Change: Unchangeable
Value Range:
–10.00 V to 10.00 V
Description
This parameter shows the current corrected AI2 input.
U2-20
Power supply unit I/O - usage of DI1 by drive unit
Address:
29204
Min.:
0
Unit:
-
Max.: 8 Data type: UInt16

Table of Contents