Parameter Group
-233-
Min.:
0
Unit:
-
Max.: 500 Data type: UInt16
Default:
10
Change:
At once
Value Range:
0 to 500
Description
This parameter defines the acceleration compensation filter time.
F2-27
Overvoltage suppression in vector control mode
Address:
61979
Min.:
0
Unit:
-
Max.: 1 Data type: UInt16
Default:
1
Change:
At once
Value Range:
0: Disabled
1: Enabled
Description
This parameter defines whether to enable overvoltage suppression in vector control mode.
F2-28
Torque filter cut-off frequency
Address:
61980
Min.:
50
Unit:
Hz
Max.: 1000 Data type: UInt16
Default:
500
Change:
At once
Value Range:
50 Hz to 1000 Hz
Description
This parameter defines the cut-off frequency of the torque filter. It can be adjusted based on the
torque source.
F2-29
Synchronous motor initial angle detection current
Address:
61981
Min.:
50
Unit:
-
Max.: 180 Data type: UInt16
Default:
80
Change:
At once
Value Range:
50 to 180
Description
This parameter defines the initial angle detection current of the synchronous motor. The default
value is recommended.
F2-30
Speed loop parameter auto-calculation
Address:
61982
Min.:
0
Unit:
-
Max.: 1 Data type: UInt16
Default:
0
Change:
At stop
Value Range:
0: Disabled
1: Enabled
Description
Speed loop parameter auto-calculation