Parameter Group
-249-
50: Wobble pause
In the wobble process, when this terminal is active, the wobble function is paused (the AC drive
outputs at the center frequency).
54 to 63: Reserved
F4-02
DI2 hardware source
Address:
62466
Min.:
0
Unit:
-
Max.: 208 Data type: UInt16
Default:
0
Change:
At stop
Value Range:
Same as F4-00
Description
Same as F4-00
F4-03
DI2 function selection
Address:
62467
Min.:
0
Unit:
-
Max.: 63 Data type: UInt16
Default:
4
Change:
At stop
Value Range:
Same as F4-01
Description
Same as F4-01
F4-04
DI3 hardware source
Address:
62468
Min.:
0
Unit:
-
Max.: 208 Data type: UInt16
Default:
0
Change:
At stop
Value Range:
Same as F4-00
Description
Same as F4-00
F4-05
DI3 function selection
Address:
62469
Min.:
0
Unit:
-
Max.: 63 Data type: UInt16
Default:
9
Change:
At stop
Value Range:
Same as F4-01
Description
Same as F4-01
F4-06
DI4 hardware source
Address:
62470
Min.:
0
Unit:
-
Max.: 208 Data type: UInt16
Default:
0
Change:
At stop
Value Range:
Same as F4-00