Loading...
Parameter Group
-258-
Description
This parameter defines the x-axis of the maximum input point on AI curve 3, that is, the maximum
analog input voltage (or maximum analog input current).
F4-42
Percentage corresponding to AI curve 3 maximum input
Address:
62506
Min.:
–100.0
Unit:
%
Max.: 100.0 Data type: Int16
Default:
100.0
Change:
At once
Value Range:
–100.0% to 100.0%
Description
This parameter defines the y-axis of the maximum input point on AI curve 3, that is, the percentage of
the maximum analog input relative to the maximum frequency.
F4-48
AI curve selection
Address:
62512
Min.:
0
Unit:
-
Max.: 555 Data type: UInt16
Default:
321
Change:
At once
Value Range:
Ones:
1: Curve 1 (2 points)
2: Curve 2 (2 points)
3: Curve 3 (2 points)
4: Curve 4 (4 points)
5: Curve 5 (4 points)
Tens:
1: Curve 1 (2 points)
2: Curve 2 (2 points)
3: Curve 3 (2 points)
4: Curve 4 (4 points)
5: Curve 5 (4 points)
Hundreds:
1: Curve 1 (2 points)
2: Curve 2 (2 points)
3: Curve 3 (2 points)
4: Curve 4 (4 points)
5: Curve 5 (4 points)
Description