Parameter Group
-368-
Default:
0
Change:
At stop
Value Range:
0: Disabled
1: Enabled
Description
This parameter defines whether to enable low-speed closed-loop current (for VVC). The default value
is recommended.
A9-41
Low-speed closed-loop current (for VVC)
Address:
43305
Min.:
30
Unit:
-
Max.: 200 Data type: UInt16
Default:
50
Change:
At stop
Value Range:
30 to 200
Description
This parameter defines the low-speed closed-loop current (for PMVVC). The default value is
recommended.
A9-42
Oscillation suppression damping coefficient (for VVC)
Address:
43306
Min.:
0
Unit:
-
Max.: 500 Data type: UInt16
Default:
100
Change:
At once
Value Range:
0 to 500
Description
This parameter defines the oscillation suppression damping coefficient (for PMVVC). The default value
is recommended.
A9-43
Initial position compensation angle (for VVC)
Address:
43307
Min.:
0
Unit:
-
Max.: 5 Data type: UInt16
Default:
0
Change:
At stop
Value Range:
0 to 5
Description
This parameter defines the initial position compensation angle (for PMVVC). The default value is
recommended.
A9-44
Initial position compensation angle of synchronous motor
Address:
0xA92C
Min.:
0
Unit:
-
Max.: 360 Data type: UInt16
Default:
0
Change: In real time
Value Range:
0 to 360
Description