Parameter Group
-384-
U0-05 Output power
Address:
28677
Min.:
0.0
Unit:
kW
Max.: 3276.7 Data type: Int16
Default: Model dependent Change: Unchangeable
Value Range:
0.0 kW to 3276.7 kW
Description
This parameter shows the output power (kW) of the AC drive.
U0-06 Output torque
Address:
28678
Min.:
-200.0
Unit:
%
Max.: 200.0 Data type: Int16
Default: Model dependent Change: Unchangeable
Value Range:
–200.0% to +200.0%
Description
This parameter shows the output torque (%) of the AC drive.
U0-07 DI state
Address:
28679
Min.:
-
Unit:
-
Max.:
-
Data type: UInt16
Default: Model dependent Change: Unchangeable
Value Range:
-
Description
Input state of the DI terminal of the AC drive
Bit0: DI1
Bit1: DI2
Bit2: DI3
Bit3: DI4
Bit4: DI5
Bit5: DI6
Bit6: DI7
Bit7: DI8
Bit8: VDI1
Bit9: VDI2
Bit10: VDI3
Bit11: VDI4
Bit12: VDI5
Bit13: AI1-DI
Bit14: AI2-DI
Bit15: AI3-DI
U0-08
DO/RO state
Address:
28680
Min.:
-
Unit:
-
Max.:
-
Data type: UInt16
Default:
Model dependent Change: Unchangeable
Value Range: