Parameter Group
-408-
Default:
0
Change: Unchangeable
Value Range:
0 to 65535
Description
This parameter shows the AI1 function of extension card 3 received by the AC drive.
0: Voltage input
1: Current input
2: PT100 input
3: PT1000 input
4: KTY84 input
5: PTC132 input
U5-57
Extension card 3 - AI2 function
Address:
30009
Min.:
0
Unit:
-
Max.: 65535 Data type: UInt16
Default:
0
Change: Unchangeable
Value Range:
0 to 65535
Description
This parameter shows the AI2 function of extension card 3 received by the AC drive.
0: Voltage input
1: Current input
2: PT100 input
3: PT1000 input
4: KTY84 input
5: PTC132 input
U5-60
Power supply unit - AI1 voltage
Address:
30012
Min.:
0
Unit:
-
Max.: 65535 Data type: Int16
Default:
0
Change: Unchangeable
Value Range:
0 to 65535
Description
This parameter shows the AI1 voltage of the power supply unit received by the AC drive.
U5-61
Power supply unit - AI2 voltage
Address:
30013
Min.:
0
Unit:
-
Max.: 65535 Data type: Int16
Default:
0
Change: Unchangeable
Value Range:
0 to 65535
Description
This parameter shows the AI2 voltage of the power supply unit received by the AC drive.
U5-62
Extension card 1 - AI1 voltage
Address:
30014
Min.:
0
Unit:
-