Parameter Group
-41-
1: Operation enable
The power supply unit sends a running command to the drive unit.
2: Incoming circuit breaker feedback
The power supply unit sends a running command to the drive unit according to feedback signals.
3: Auxiliary circuit breaker feedback
The power supply unit sends a running command to the drive unit according to feedback signals.
4: Residual current device feedback
The power supply unit sends a running command to the drive unit according to feedback signals.
5: Fault reset
An input terminal programmed with this function can be used to reset the AC drive when a fault
occurs.
6: Operation disabled for drive unit
The power supply unit sends a command to prohibit running of the drive unit.
7: Drive unit coast to stop
The power supply unit sends a coast to stop command to the drive unit.
8: Drive unit stop according to preset mode
The power supply unit sends a command to the drive unit to stop it according to the preset stop
mode.
F4-02
DI2 hardware source
Address:
62466
Min.:
0
Unit:
-
Max.: 208 Data type: UInt16
Default:
0
Change:
At stop
Value Range:
Same as F4-00
Description
Same as F4-00
F4-03
DI2 function selection
Address:
62467
Min.:
0
Unit:
-
Max.: 8 Data type: UInt16
Default:
0
Change:
At stop
Value Range:
Same as F4-01
Description
Same as F4-01
F4-04
DI3 hardware source
Address:
62468
Min.:
0
Unit:
-
Max.: 208 Data type: UInt16
Default:
0
Change:
At stop
Value Range:
Same as F4-00
Description
Same as F4-00
F4-05
DI3 function selection
Address:
62469