Function Applications
-460-
Table 4–15 Parameters related to the drive unit
Para. No. Name
Default
Value Range Description
F4-00
DI1 hardware source
0
0: None
1: DI1 of the power supply
unit
2: DI2 of the power supply
unit
3: DI3 of the power supply
unit
4: DI4 of the power supply
unit
5: DIO1 of the power supply
unit
6: DIO2 of the power supply
unit
7: DIO3 of the power supply
unit
8: DIO4 of the power supply
unit
101: DI1 of extension card 1
102: DI2 of extension card 1
103: DI3 of extension card 1
104: DI4 of extension card 1
105: DI5 of extension card 1
106: DI6 of extension card 1
107: DI7 of extension card 1
108: DI8 of extension card 1
201: DI1 of extension card 2
202: DI2 of extension card 2
203: DI3 of extension card 2
204: DI4 of extension card 2
205: DI5 of extension card 2
206: DI6 of extension card 2
207: DI7 of extension card 2
208: DI8 of extension card 2
This parameter defines
the source of the input
terminal.
F4-02
DI2 hardware source
0
F4-04
DI3 hardware source
0
F4-06
DI4 hardware source
0
F4-08
DI5 hardware source
0
F4-10
DI6 hardware source
0
F4-12 DI7 hardware source
0
F4-14
DI8 hardware source
0
The value range of the parameters in the preceding table changes automatically.
1. If extension cards 1 and 2 are not connected, non-existent hardware resources are skipped
automatically when parameters are set on the local operating panel, and a write failure will be
reported when the parameters are set to non-existent hardware resources at the background or by
using an external operating panel
For example, if extension card 1 is not connected, the value of F4-00 (DI1 hardware source) will jump
directly from 008 to 201 when you press the UP key.
2. For the same drive unit, the values of the parameters in the preceding table cannot be duplicate
(that is, different DIs cannot use the same hardware source). If a hardware source has been selected,