Function Applications
-473-
Table 4–23 Parameters of the power supply unit (A1 - I/O extension card of the power supply unit)
Para. No. Name
Default
Value Range Description
A1-05
AI1 filter time
0.01s 0.00 to 10.00s
This parameter defines the AI input filter
time of the power supply unit, which is
0.1s by default. It is set based on the
response requirements and field signal
interference. Decrease this filter time if
fast response is required, and increase it
if field interference is strong.
A1-06
AI2 filter time
0.01s 0.00 to 10.00s
A1-10
AI1 input
0
0: Voltage input
1: Current input
2: Temperature
input PT100
3: Temperature
input PT1000
4: Temperature
input KTY84-130
5: Temperature
input PTC-130
This parameter defines the AI input
function of the power supply unit.
A1-11
AI2 input
0
Table 4–24 Parameters of the power supply unit (A2 - I/O extension card 1)
Para. No. Name
Default
Value Range Description
A2-05
AI1 filter time
0.01s 0.00 to 10.00s
This parameter defines the AI input
filter time of extension card 1,
which is 0.1s by default. It is set
based on the response
requirements and field signal
interference. Decrease this filter
time if fast response is required,
and increase it if field interference
is strong.
A2-06
AI2 filter time
0.01s 0.00 to 10.00s
A2-10
AI1 input
0
0: Voltage input
1: Current input
2: Temperature input
PT100
3: Temperature input
PT1000
4: Temperature input
KTY84-130
5: Temperature input
PTC-130
This parameter defines the AI input
function of extension card 1.
A2-11
AI2 input
0

Table of Contents