Parameter Group
-47-
F4-31
DI8 inactive delay
Address:
62495
Min.:
0.00
Unit:
s
Max.: 600.00 Data type: UInt16
Default:
0.00
Change:
At once
Value Range:
0.00s to 600.00s
Description
Same as F4-24
F4-32
DI (DI1 to DI5) active mode
Address:
62496
Min.:
0
Unit:
-
Max.: 11111 Data type: UInt16
Default:
0
Change:
At once
Value Range:
Ones: DI1 active mode
Tens: DI2 active mode
Hundreds: DI3 active mode
Thousands: DI4 active mode
Ten thousands: DI5 active mode
0: Active low
1: Active high
Description
When active high is selected, the DI terminal is active when connected to COM and inactive when
disconnected from COM.
When active low is selected, the DI terminal is inactive when connected to COM and active when
disconnected from COM.
F4-33
DI (DI6 to DI8) active mode
Address:
62497
Min.:
0
Unit:
-
Max.: 11111 Data type: UInt16
Default:
0
Change:
At once
Value Range:
Ones: DI6 active mode
Tens: DI7 active mode
Hundreds: DI8 active mode
0: Active low
1: Active high
Description
When active high is selected, the DI terminal is active when connected to COM and inactive when
disconnected from COM.
When active low is selected, the DI terminal is inactive when connected to COM and active when
disconnected from COM.