Function Applications
-495-
Figure 4-44 Application scenario of the wobble function
Figure 4-45 Schematic diagram of the wobble function
Table 4–31 Related parameters
Para.
No.
Name
Default
Value Range Description
Fb-00
Swing setting mode
0
0: Relative to the
center frequency
1: Relative to the
maximum
frequency
0: Relative to center frequency (F0-07,
frequency reference superposition). This mode
applies to variable swing systems, in which the
swing changes with the center frequency
(frequency reference).
1: Relative to the maximum frequency (F0-10,
maximum frequency). This mode applies to
fixed swing systems, in which the swing is a
fixed value calculated based on the maximum
frequency.
Fb-01
Wobble amplitude
0.0% 0.0% to 100.0%
When Fb-01 is set to 0, the swing is 0,
indicating that the wobble function is
disabled.