EasyManua.ls Logo

Inovance MD800 Series - Page 560

Inovance MD800 Series
565 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Fault Name
Display
Possible Cause Solution
Fault Type
Motor auto-tuning
error
E22.00
The stator resistance
obtained through auto-
tuning exceeds the allowed
range.
Check whether the rated motor voltage and current
are correctly set, and set F1-02 (rated motor voltage)
and F1-03 (rated motor current) according to the
motor nameplate.
Perform auto-tuning after the motor stops.
Axis fault
E22.01
The rotor resistance of the
asynchronous motor
obtained through auto-
tuning exceeds the allowed
range.
Axis fault
E22.02
The no-load current and
mutual inductance of the
asynchronous motor
obtained through auto-
tuning exceed the allowed
range. If such an alarm is
generated, the AC drive
calculates no-load current
and mutual inductance
based on known parameters,
which may be different from
the optimal values.
Set motor parameters in group F1 according to the
motor nameplate.
Before auto-tuning, ensure that the motor has no
load.
Axis fault
E22.03
The back EMF of the
synchronous motor obtained
through auto-tuning exceeds
the allowed range.
Ensure that the rated motor voltage (F1-02) is set
according to the motor nameplate.
Before auto-tuning, ensure that the motor has no
load.
Axis fault
List of Fault Codes