Chapter 8 Advanced 162
It specifies whether to enable the SNMP agent function of the CPE. By default,
it is disabled.
An SNMP manager and the SNMP agent can communicate with each other
only if their SNMP versions are the same. Currently, the SNMP agent function
of the CPE supports SNMP V1 and SNMP V2C.
It specifies the device name of the CPE. The default device name is the model
and version number of theCPE.
It is recommended that you change the device name so that you can easily
identify the CPE when managing it using SNMP.
It specifies the read password shared between SNMP managers and this
SNMP agent. The default password is public.
The SNMP agent function of the device allows an SNMP manager to use the
password to read variables in the MIB of the device.
It specifies the read/write password shared between SNMP managers and
this SNMP agent. The default password is private.
The SNMP agent function of the device allows an SNMP manager to use the
password to read/write variables in the MIB of the device.
It specifies the location where the CPE is used. You can change the location as
required.
Example of configuring the SNMP function
Network requirement
− The CPE connects to an NMS over an LAN. This network address of the CPE is
192.168.2.1/24 and the network IP address of the NMS is 192.168.2.212/24.
− The NMS use SNMP V1 or SNMP V2C to monitor and manage the CPE.
− Assume that Read Community is Jack, and Read/Write Community is Jack123.