EasyManua.ls Logo

KEMPOWER Power Unit - Static (S4) - 4 Single Satellites; Static (S4) - 2 Double Satellites

KEMPOWER Power Unit
167 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
10.9. Static (S4) – 4 single Satellites
Table 13. S4 connected to 4 single Satellites (4 x 125 A/75 A configuration output)
Config.
output
ChargEye con-
nector
Max. current Terminals
DC output Control cable DC input Control cable
1 12 (right) 125 A/75 A Power Unit 1 Satellite 1
OUT 1 CT 1 CAB 1 CT A
2 22 (right) 125 A/75 A Power Unit 1 Satellite 2
OUT 2 CT 2 CAB 1 CT A
3 32 (right) 125 A/75 A Power Unit 1 Satellite 3
OUT 3 CT 3 CAB 1 CT A
4 42 (right) 125 A/75 A Power Unit Satellite 4
OUT 4 CT 4 CAB 1 CT A
10.10. Static (S4) – 2 double Satellites
Table 14. S4 connected to 2 double Satellites (4 x 125 A/75 A configuration output)
Config.
output
ChargEye
connector
Max. current Terminals
DC output Control cable DC input Control cable
1 12 (right) 125 A/75 A Power Unit 1 Satellite 1
OUT 1 CT 1 CAB 1 CT A
2 11 (left) 125 A/75 A Power Unit 1 Satellite 1
OUT 2 CT 2 CAB 2 CT B
3 22 (right) 125 A/75 A Power Unit 1 Satellite 2
OUT 3 CT 3 CAB 1 CT A
4 21 (left) 125 A/75 A Power Unit Satellite
OUT 4 CT 4 CAB 2 CT B
CHARGING EQUIPMENT FOR ELECTRIC VEHICLES INSTALLATION MANUAL
CONFIDENTIAL – CERTIFIED PARTNERS 137 REV 2.40 EN 04-2024

Table of Contents

Related product manuals