The specific requirements and ambient conditions of the site:
If you plan to install the charging power unit in a closed space,
contact
Kempower Sales Support to approve the location before
installation. If the unit is installed indoors, make sure that the air
flow to the unit is sufficient.
If the temperature stays above 30 °C for long periods of time, we
recommend placing the charging power unit in a well-ventilated
shelter with the display screen facing away from direct sunlight. For
assistance, contact
Kempower Sales Support.
The location of the main supply point: supply grid main distribution
board or one of the secondary substations.
The configuration of your communication system. Connectivity
to the Kempower ChargEye and possible OCPP backend system
requires an Internet connection, either with a SIM card or Ethernet
(SuperCat 6/7 shielded) cabling to your wide area network (WAN)
router.
The charging power unit must be easily accessible for
maintenance without disturbing traffic or other movement in the
charging area.
The charging points must be easily accessible to the end users.
The maximum distance between the charging power unit and a
connected charging point is approximately 80 m.
4.1. Mechanical planning
NOTE
See the product datasheets for the dimensions and weights of the units. Product
datasheets are available at
mediabank.kempower.com.
As the requirements of individual installations vary significantly, it is not
possible to give detailed instructions that are valid for all sites. Take
into account the local rules and requirements on civil works, electrical
installations, cable routing, and cable dimensioning. For assistance, contact
Kempower Sales Support.
The Kempower delivery includes the charging equipment and cabling inside
the units. The steel base is the standard installation foundation for the
Station Charger, and it is included in the delivery. If the cables are routed
above the ground, order the optional steel base for the Power Unit to
add installation space below the unit. See
3.5: Steel base (option).
The standard installation flange of the Satellite cannot be used if the
Satellite is installed in a prefabricated concrete element typically used for
CHARGING EQUIPMENT FOR ELECTRIC VEHICLES INSTALLATION MANUAL
CONFIDENTIAL – CERTIFIED PARTNERS 34 REV 2.40 EN 04-2024