Indicative cable type
•
7 x 1.5 mm
2
Cu cable
• Control signal wire
• Auxiliary power wire for the user interface of the satellite (+24 V)
• Ground wire (GND, 0 V)
4.2.2.3. Communication cable
NOTE
Each Satellite must have its own communication cable. The communication cable is
not included in the delivery.
Indicative cable type
• SuperCat 6/7 shielded Ethernet cable 4 x 2 x 0.25 mm
2
The Ethernet shield is grounded at one end only, either charging power unit
or Satellite.
Connectivity to the Kempower ChargEye and possible OCPP backend
system requires an Internet connection, either with a SIM card in the control
module of the master charging power unit or Ethernet cabling between your
wide area network (WAN) router and the master charging power unit.
4.2.3. AC Satellite cabling
NOTICE
Do not connect the Ethernet cable of AC Satellite to the charging power unit. Doing so
will stop the operation of both units.
NOTE
AC Satellite is not connected to a charging power unit. It is connected directly to the
main power supply.
• The AC Satellite requires only AC mains power cables.
•
An Ethernet cable between the AC Satellite and the site Ethernet
network is optional but not required. The indicative cable type
is SuperCat 6/7 shielded Ethernet cable 4 x 2 x 0.25 mm
2
. Connectivity to
the Kempower ChargEye and possible OCPP backend system requires
an Internet connection, either with a SIM card or Ethernet cabling to your
wide area network (WAN) router.
• Each charging socket or vehicle connector of the AC Satellite has
dedicated residual-circuit monitoring (RCM). Obey local laws and
CHARGING EQUIPMENT FOR ELECTRIC VEHICLES INSTALLATION MANUAL
CONFIDENTIAL – CERTIFIED PARTNERS 40 REV 2.40 EN 04-2024