Fig.12: Name plate 1, frequency inverter (example)
1 Enclosure 2 Type series, size
3 Nominal power 4 Nominal current
5 Mains frequency 6 Mains voltage
Fig.13: Name plate 2, frequency inverter (example)
1 PumpDrive type code 2 KSB order number
3 Pump designation 4 Date of manufacture
6.4 Power range and sizes
Table22: Power range
4)
for 2-pole (3000rpm), 4-pole (1500rpm) and 6-pole (1000) asynchronous motors and KSB
SuPremE
Size Nominal electrical power Nominal output current Mains-side input current
[kW] [A] [A]
A 0,37 1,3 1,4
0,55 1,8 2
0,75 2,5 2,7
1,10 3,5 3,7
1,50 4,9 5,2
B 2,2 6 6,3
3,0 8 8,4
4,0 10 10,4
C 5,5 14 14,6
7,5 18 18,7
11 25 25,9
D 15 33 34,1
18,5 42 43,3
22 51 52,4
30 66 67,7
E 37 81,5 83,4
4) The power ranges specified apply in full to all mounting options.