10 Parameter List
PumpDrive 2
135 of
212
10 Parameter List
Table111: Overview of parameters
Parameter Description Help text Possible settings Unit Factory setting
1 Operation - - - -
1-1 Login - - - -
1-1-1 Customer Login Log in as customer 0000…9999
1-1-2 Service Login Log in for access to special parameters for
KSB Service
0000…9999
1-1-3 Factory Login Log in for access to special parameters for
KSB Production
0000…9999
1-1-4 Logout Logout from all access levels Run
1-1-5 Customer Access ID Changing the customer access ID 0000…9999
1-1-6 Service Access ID Changing the customer service ID 0000…9999
1-2 Operating Values
1-2-1 Motor and Frequency
Inverter
1-2-1-1 Speed Current speed of motor rpm
1-2-1-2 Motor Input Power Current effective power of motor Dependent on the
unit set
1-2-1-3 Pump Input Power Current mechanical power of pump Dependent on the
unit set
1-2-1-4 Pump Set Input Power Current effective power of pump set (pump
set = frequency inverter + motor + pump)
Dependent on the
unit set
1-2-1-5 Motor Current Current output current of frequency
inverter. Losses and/or discharge currents
can cause the actual motor current to differ
from the output current of the frequency
inverter.
A
1-2-1-6 Motor Voltage Current output voltage of frequency
inverter. Long motor cables and/or filters
can cause the voltage at the motor terminal
board to differ from the output voltage of
the frequency inverter.
V
1-2-1-7 Output Frequency Current output frequency of frequency
inverter
Hz
1-2-1-8 DC Link Voltage Current DC link voltage of frequency
inverter
V